{"id":9600,"date":"2025-09-01T06:31:52","date_gmt":"2025-09-01T06:31:52","guid":{"rendered":"https:\/\/ecoexperts.at\/eco-traffic-light-control-unit\/"},"modified":"2025-09-01T06:31:54","modified_gmt":"2025-09-01T06:31:54","slug":"eco-traffic-light-control-unit","status":"publish","type":"page","link":"https:\/\/ecoexperts.at\/en\/eco-traffic-light-control-unit\/","title":{"rendered":"ECO-Traffic light control unit"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><p>[vc_row][vc_column][vc_row_inner][vc_column_inner width=&#8221;1\/2&#8243;]<div id=\"ultimate-heading-798769e493f407d5a\" class=\"uvc-heading ult-adjust-bottom-margin ultimate-heading-798769e493f407d5a uvc-3958  uvc-heading-default-font-sizes\" data-hspacer=\"no_spacer\"  data-halign=\"center\" style=\"text-align:center\"><div class=\"uvc-heading-spacer no_spacer\" style=\"top\"><\/div><div class=\"uvc-main-heading ult-responsive\"  data-ultimate-target='.uvc-heading.ultimate-heading-798769e493f407d5a h2'  data-responsive-json-new='{\"font-size\":\"\",\"line-height\":\"\"}' ><h2 style=\"--font-weight:theme;margin-bottom:50px;\">Intelligent traffic light control<\/h2><\/div><\/div>[vc_column_text css=&#8221;&#8221;]The ECO-AMPEL control unit can be used to control and monitor traffic light systems. The control unit provides all essential information via potential-free contacts, enabling the traffic lights to be controlled and monitored using standard IO modules.<br \/>A second 160V power supply input is used for night-time dimming. This allows day-night switching to be implemented without additional electrical components.<br \/>The ECO-AMPEL control unit is based on a microcontroller and is equipped with modular and powerful system software.<br \/>The ECO-AMPEL control unit meets the requirements of RVS 09.02.22, PlaPB 800.563 (ASFINAG BuS) and PlaPB 800.552 (ASFINAG TIFL). It can be used to implement applications in accordance with \u00d6NORM EN 12675 and OVE EN 50556.[\/vc_column_text][\/vc_column_inner][vc_column_inner width=&#8221;1\/2&#8243;][vc_single_image image=&#8221;9559&#8243; img_size=&#8221;full&#8221; alignment=&#8221;center&#8221; css=&#8221;.vc_custom_1747656781521{margin-top: 30px !important;margin-right: 30px !important;margin-bottom: 30px !important;margin-left: 30px !important;}&#8221;][\/vc_column_inner][\/vc_row_inner][\/vc_column][\/vc_row][vc_row css=&#8221;.vc_custom_1747286679582{margin-top: 30px !important;}&#8221;][vc_column][vc_row_inner][vc_column_inner width=&#8221;1\/2&#8243;]<div id=\"ultimate-heading-544369e493f407e5a\" class=\"uvc-heading ult-adjust-bottom-margin ultimate-heading-544369e493f407e5a uvc-8932  uvc-heading-default-font-sizes\" data-hspacer=\"no_spacer\"  data-halign=\"center\" style=\"text-align:center\"><div class=\"uvc-heading-spacer no_spacer\" style=\"top\"><\/div><div class=\"uvc-main-heading ult-responsive\"  data-ultimate-target='.uvc-heading.ultimate-heading-544369e493f407e5a h2'  data-responsive-json-new='{\"font-size\":\"\",\"line-height\":\"\"}' ><h2 style=\"--font-weight:theme;margin-bottom:50px;\">Available variants <\/h2><\/div><\/div><div class=\"standard-arrow list-divider bullet-top\"><ul>\n<li>ECO-AMPEL-1: Control unit for 1x three-phase traffic light including local control on the device<\/li>\n<li>ECO-AMPEL-2: Control unit for 2x three-phase traffic lights including local control on the device<\/li>\n<li><em>(other versions available on request)<\/em><\/li>\n<\/ul>\n<\/div>[\/vc_column_inner][vc_column_inner width=&#8221;1\/2&#8243;]<div id=\"ultimate-heading-721069e493f40800f\" class=\"uvc-heading ult-adjust-bottom-margin ultimate-heading-721069e493f40800f uvc-4184  uvc-heading-default-font-sizes\" data-hspacer=\"no_spacer\"  data-halign=\"center\" style=\"text-align:center\"><div class=\"uvc-heading-spacer no_spacer\" style=\"top\"><\/div><div class=\"uvc-main-heading ult-responsive\"  data-ultimate-target='.uvc-heading.ultimate-heading-721069e493f40800f h2'  data-responsive-json-new='{\"font-size\":\"\",\"line-height\":\"\"}' ><h2 style=\"--font-weight:theme;margin-bottom:50px;\">Technical Data<\/h2><\/div><\/div><div class=\"standard-arrow list-divider bullet-top\"><ul>\n<li>Compatibility with traffic lights: SWARCO FUTURLED 6 \u2013 230VAC \/ others on request<\/li>\n<\/ul>\n<ul>\n<li>Power supply: 24 V DC +\/-10%<\/li>\n<li>Operating voltage (traffic lights): 196..253 V AC (day), 150 V..170 V AC (night, dimmed)<\/li>\n<li>Nominal power: min. 8 W\/4 W per channel<\/li>\n<li>Maximum power: 25 W per channel<\/li>\n<li>Monitoring: Operating current monitoring when switched on via current measurement (&lt;75% of nominal current), quiescent current monitoring (cyclical test) when switched off for each signal light below the switch-on voltage<\/li>\n<li>Processor: ARM processor<\/li>\n<li>Software architecture: C++ firmware, firmware update via RS485<\/li>\n<li>Protocols\/interfaces: MODBUS RTU\/ASCII protocol via RS485<\/li>\n<li>Operating temperature: -25\u00b0C to +60\u00b0C<\/li>\n<li>Storage temperature: -25\u00b0C to +80\u00b0C<\/li>\n<li>Humidity: 5% to 90% r.h., non-condensing<\/li>\n<li>Housing: Plastic, 8 division units 8TE (8TE)<\/li>\n<li>Protection class IP: IP20<\/li>\n<li>Equipment protection class: Class 2<\/li>\n<li>Approval\/marking: CE<\/li>\n<li>Housing width x height x depth: 143 mm \/ 8 TE x 110 mm x 62 mm<\/li>\n<li>Weight: 400 g<\/li>\n<\/ul>\n<\/div>[\/vc_column_inner][\/vc_row_inner][\/vc_column][\/vc_row][vc_row css=&#8221;.vc_custom_1747286679582{margin-top: 30px !important;}&#8221;][vc_column][vc_row_inner][vc_column_inner width=&#8221;1\/2&#8243;]<div id=\"ultimate-heading-174169e493f40816e\" class=\"uvc-heading ult-adjust-bottom-margin ultimate-heading-174169e493f40816e uvc-2421  uvc-heading-default-font-sizes\" data-hspacer=\"no_spacer\"  data-halign=\"center\" style=\"text-align:center\"><div class=\"uvc-heading-spacer no_spacer\" style=\"top\"><\/div><div class=\"uvc-main-heading ult-responsive\"  data-ultimate-target='.uvc-heading.ultimate-heading-174169e493f40816e h2'  data-responsive-json-new='{\"font-size\":\"\",\"line-height\":\"\"}' ><h2 style=\"--font-weight:theme;margin-bottom:50px;\">Detailed specification<\/h2><\/div><\/div><div class=\"standard-arrow list-divider bullet-top\"><ul>\n<li>Status display of the control unit via status LED<\/li>\n<li>Traffic light connection Terminal type RM5, cable cross-section: max. 2.5 mm\u00b2, M3 tightening torque: max. 0.5 Nm<\/li>\n<li>Signals Terminal type RM3.5, cable cross-section: max. 1.5 mm\u00b2, M2 tightening torque: max. 0.2 Nm<\/li>\n<li>LED display for the traffic light status for each traffic light (RED, YELLOW, GREEN)<\/li>\n<li>Traffic light fault indication by rapid flashing of the corresponding LED<\/li>\n<li>Operating mode switch and selection button for manual control (local mode) on the device<\/li>\n<li>Blue LED indicators for selection display of manual control on the device<\/li>\n<li>Measurement of the AC supply voltage for function monitoring<\/li>\n<li>Function check for each light source in the on and off state<\/li>\n<li>Integrated fuse for day and night supply<\/li>\n<li>Selectable colour sequence types can be parameterised: red-yellow-green, yellow, red, red-yellow, red-green<\/li>\n<li>Selectable mode: direct switching of inputs or STVO-compliant colour sequence switching,<\/li>\n<li>blocking of invalid traffic light states<\/li>\n<li>System parameterisation and status query via Modbus\/RS485:<\/li>\n<li>#After a power failure and subsequent power restoration, yellow<\/li>\n<li>flashing (time parameterisable) and then signal switching as required<\/li>\n<li>#Default switching also via Modbus\/RS485<\/li>\n<li>Flashing synchronised with external flashing clock or internal flashing clock; if the external flashing clock fails, there is an automatic switch to the internal flashing clock<\/li>\n<\/ul>\n<\/div>[\/vc_column_inner][vc_column_inner width=&#8221;1\/2&#8243;]<div id=\"ultimate-heading-319569e493f4082c9\" class=\"uvc-heading ult-adjust-bottom-margin ultimate-heading-319569e493f4082c9 uvc-637  uvc-heading-default-font-sizes\" data-hspacer=\"no_spacer\"  data-halign=\"center\" style=\"text-align:center\"><div class=\"uvc-heading-spacer no_spacer\" style=\"top\"><\/div><div class=\"uvc-main-heading ult-responsive\"  data-ultimate-target='.uvc-heading.ultimate-heading-319569e493f4082c9 h2'  data-responsive-json-new='{\"font-size\":\"\",\"line-height\":\"\"}' ><h2 style=\"--font-weight:theme;margin-bottom:50px;\">Connection<\/h2><\/div><\/div><div class=\"standard-arrow list-divider bullet-top\"><p><b><strong>Supply voltage<\/strong><\/b><\/p>\n<ul>\n<li>24 volts DC<\/li>\n<li>230 V AC for daytime operation<\/li>\n<li>160 V AC for night-time operation<\/li>\n<\/ul>\n<p><b><strong>Connection per traffic light<\/strong><\/b><\/p>\n<ul>\n<li>Red output<\/li>\n<li>Yellow output<\/li>\n<li>Green output<\/li>\n<li>Neutral conductor<\/li>\n<\/ul>\n<p><b><strong>Digital inputs<\/strong><\/b><\/p>\n<ul>\n<li>TN \u2026.Day\/night<\/li>\n<li>BL\u2026External flashing cycle<\/li>\n<li>IN\u2026Depending on variant<\/li>\n<li>Per traffic light<\/li>\n<li>o RT\u2026Red circuit<\/li>\n<li>o GE\u2026Yellow circuit<\/li>\n<li>o GN\u2026Green circuit<\/li>\n<li>o AU\u2026Off<\/li>\n<\/ul>\n<p><b>Digital outputs<\/b><\/p>\n<ul>\n<li>Faults per traffic light<\/li>\n<li>o RT\u2026Red lamp fault (low in case of fault)<\/li>\n<li>o GE\u2026Yellow lamp fault (low in case of fault)<\/li>\n<li>o GN\u2026Green lamp fault (low in case of fault)<\/li>\n<li>o AL\u2026Total fault (low in case of fault)<\/li>\n<li>o TS\u2026Local operating mode (low in case of local)<\/li>\n<li>Operating messages of the switched outputs per traffic light (including current monitoring)<\/li>\n<li>o RT\u2026Red<\/li>\n<li>o GE\u2026Yellow<\/li>\n<li>o GN\u2026Green<\/li>\n<li>o TN\u2026Day\/night<\/li>\n<\/ul>\n<\/div>[\/vc_column_inner][\/vc_row_inner][\/vc_column][\/vc_row][vc_row css=&#8221;.vc_custom_1747286679582{margin-top: 30px !important;}&#8221;][vc_column][vc_row_inner][vc_column_inner]<div id=\"ultimate-heading-850669e493f40847e\" class=\"uvc-heading ult-adjust-bottom-margin ultimate-heading-850669e493f40847e uvc-2964  uvc-heading-default-font-sizes\" data-hspacer=\"no_spacer\"  data-halign=\"center\" style=\"text-align:center\"><div class=\"uvc-heading-spacer no_spacer\" style=\"top\"><\/div><div class=\"uvc-main-heading ult-responsive\"  data-ultimate-target='.uvc-heading.ultimate-heading-850669e493f40847e h2'  data-responsive-json-new='{\"font-size\":\"\",\"line-height\":\"\"}' ><h2 style=\"--font-weight:theme;margin-bottom:50px;\">Assembly<\/h2><\/div><\/div><div class=\"standard-arrow list-divider bullet-top\"><ul>\n<li>Mounting type: Top-hat rail mounting on standard profile rail EN 60715 35&#215;7.5\/15 snap-on or rear panel mounting<\/li>\n<li>Mounting width x height x depth: 143 mm \/ 8 TE x 170 mm x 62 mm<\/li>\n<li>Distances to be maintained: top\/bottom: 30 mm, side: 0 mm<\/li>\n<\/ul>\n<\/div>[\/vc_column_inner][\/vc_row_inner][\/vc_column][\/vc_row][vc_row css=&#8221;.vc_custom_1621493283045{margin-top: 20px !important;}&#8221;][vc_column width=&#8221;1\/2&#8243;][vc_column_text css=&#8221;.vc_custom_1747287981466{margin-bottom: 30px !important;}&#8221;]<\/p>\n<h4>Information brochure as PDF<\/h4>\n<p>You can find more information about the ECO-AMPEL control unit in our product data sheet. Simply fill out the form and you will receive the PDF immediately.[\/vc_column_text]<style id=\"wpforms-css-vars-9519\">\n\t\t\t\t#wpforms-9519 {\n\t\t\t\t\n\t\t\t}\n\t\t\t<\/style><div class=\"wpforms-container wpforms-container-full wpforms-render-modern\" id=\"wpforms-9519\"><form id=\"wpforms-form-9519\" class=\"wpforms-validate wpforms-form wpforms-ajax-form\" data-formid=\"9519\" method=\"post\" enctype=\"multipart\/form-data\" action=\"\/en\/wp-json\/wp\/v2\/pages\/9600\" data-token=\"df7c510477ffab39429db954da91f929\" data-token-time=\"1776587764\"><noscript class=\"wpforms-error-noscript\">Please enable JavaScript in your browser to complete this form.<\/noscript><div id=\"wpforms-error-noscript\" style=\"display: none;\">Please enable JavaScript in your browser to complete this form.<\/div><div class=\"wpforms-field-container\"><div id=\"wpforms-9519-field_1-container\" class=\"wpforms-field wpforms-field-name\" data-field-id=\"1\"><fieldset><legend class=\"wpforms-field-label wpforms-label-hide\" aria-hidden=\"false\">Name <span class=\"wpforms-required-label\" aria-hidden=\"true\">*<\/span><\/legend><div class=\"wpforms-field-row wpforms-field-large\"><div class=\"wpforms-field-row-block wpforms-first wpforms-one-half\"><input type=\"text\" id=\"wpforms-9519-field_1\" class=\"wpforms-field-name-first wpforms-field-required\" name=\"wpforms[fields][1][first]\" placeholder=\"Vorname*\" aria-errormessage=\"wpforms-9519-field_1-error\" required><label for=\"wpforms-9519-field_1\" class=\"wpforms-field-sublabel after wpforms-sublabel-hide\">Vorname<\/label><\/div><div class=\"wpforms-field-row-block wpforms-one-half\"><input type=\"text\" id=\"wpforms-9519-field_1-last\" class=\"wpforms-field-name-last wpforms-field-required\" name=\"wpforms[fields][1][last]\" placeholder=\"Nachname*\" aria-errormessage=\"wpforms-9519-field_1-last-error\" required><label for=\"wpforms-9519-field_1-last\" class=\"wpforms-field-sublabel after wpforms-sublabel-hide\">Nachname<\/label><\/div><\/div><\/fieldset><\/div><div id=\"wpforms-9519-field_3-container\" class=\"wpforms-field wpforms-field-email\" data-field-id=\"3\"><label class=\"wpforms-field-label wpforms-label-hide\" for=\"wpforms-9519-field_3\" aria-hidden=\"false\">E-Mail-Adresse <span class=\"wpforms-required-label\" aria-hidden=\"true\">*<\/span><\/label><input type=\"email\" id=\"wpforms-9519-field_3\" class=\"wpforms-field-large wpforms-field-required\" name=\"wpforms[fields][3]\" placeholder=\"E-Mail-Adresse*\" spellcheck=\"false\" aria-errormessage=\"wpforms-9519-field_3-error\" required><\/div><div id=\"wpforms-9519-field_4-container\" class=\"wpforms-field wpforms-field-text\" data-field-id=\"4\"><label class=\"wpforms-field-label wpforms-label-hide\" for=\"wpforms-9519-field_4\" aria-hidden=\"false\">Firma<\/label><input type=\"text\" id=\"wpforms-9519-field_4\" class=\"wpforms-field-large\" name=\"wpforms[fields][4]\" placeholder=\"Firma\" aria-errormessage=\"wpforms-9519-field_4-error\" ><\/div><\/div><!-- .wpforms-field-container --><div class=\"wpforms-submit-container\" ><input type=\"hidden\" name=\"wpforms[id]\" value=\"9519\"><input type=\"hidden\" name=\"page_title\" value=\"\"><input type=\"hidden\" name=\"page_url\" value=\"https:\/\/ecoexperts.at\/en\/wp-json\/wp\/v2\/pages\/9600\"><input type=\"hidden\" name=\"url_referer\" value=\"\"><button type=\"submit\" name=\"wpforms[submit]\" id=\"wpforms-submit-9519\" class=\"wpforms-submit\" data-alt-text=\"Wird gesendet\u00a0\u2026\" data-submit-text=\"Absenden\" aria-live=\"assertive\" value=\"wpforms-submit\">Absenden<\/button><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/ecoexperts.at\/wp-content\/plugins\/wpforms\/assets\/images\/submit-spin.svg\" class=\"wpforms-submit-spinner\" style=\"display: none;\" width=\"26\" height=\"26\" alt=\"Loading\"><\/div><input type=\"hidden\" id=\"ct_checkjs_wpforms_4b04a686b0ad13dce35fa99fa4161c65\" name=\"ct_checkjs_wpforms\" value=\"0\" \/><script>setTimeout(function(){var ct_input_name = \"ct_checkjs_wpforms_4b04a686b0ad13dce35fa99fa4161c65\";if (document.getElementById(ct_input_name) !== null) {var ct_input_value = document.getElementById(ct_input_name).value;document.getElementById(ct_input_name).value = document.getElementById(ct_input_name).value.replace(ct_input_value, 'bf7291ab2207da9e2888f7eea01e9386f089eb59034d6f36394a9fd08ffeaaf9');}}, 1000);<\/script><input\n                    class=\"apbct_special_field apbct_email_id__wp_wpforms\"\n                    name=\"apbct__email_id__wp_wpforms\"\n                    aria-label=\"apbct__label_id__wp_wpforms\"\n                    type=\"text\" size=\"30\" maxlength=\"200\" autocomplete=\"off\"\n                    value=\"\"\n                \/><\/form><\/div>  <!-- .wpforms-container -->[vc_column_text]Occasionally it can happen that the mail ends up in the spam folder. Please also note these. Thanks![\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/2&#8243;][vc_single_image image=&#8221;9562&#8243; img_size=&#8221;full&#8221; css=&#8221;&#8221;][\/vc_column][\/vc_row]<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>[vc_row][vc_column][vc_row_inner][vc_column_inner width=&#8221;1\/2&#8243;][vc_column_text css=&#8221;&#8221;]The ECO-AMPEL control unit can be used to control and monitor traffic light systems. The control unit provides all essential information via potential-free contacts, enabling the traffic lights to be controlled and monitored using standard IO modules.A second 160V power supply input is used for night-time dimming. This allows day-night switching to be&hellip;<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-9600","page","type-page","status-publish","hentry","description-off"],"_links":{"self":[{"href":"https:\/\/ecoexperts.at\/en\/wp-json\/wp\/v2\/pages\/9600","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ecoexperts.at\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/ecoexperts.at\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/ecoexperts.at\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/ecoexperts.at\/en\/wp-json\/wp\/v2\/comments?post=9600"}],"version-history":[{"count":3,"href":"https:\/\/ecoexperts.at\/en\/wp-json\/wp\/v2\/pages\/9600\/revisions"}],"predecessor-version":[{"id":9603,"href":"https:\/\/ecoexperts.at\/en\/wp-json\/wp\/v2\/pages\/9600\/revisions\/9603"}],"wp:attachment":[{"href":"https:\/\/ecoexperts.at\/en\/wp-json\/wp\/v2\/media?parent=9600"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}