Intelligent traffic light control

The ECO-AMPEL control unit can be used to control and monitor traffic light systems. The control unit provides all essential information via potential-free contacts, enabling the traffic lights to be controlled and monitored using standard IO modules.
A second 160V power supply input is used for night-time dimming. This allows day-night switching to be implemented without additional electrical components.
The ECO-AMPEL control unit is based on a microcontroller and is equipped with modular and powerful system software.
The ECO-AMPEL control unit meets the requirements of RVS 09.02.22, PlaPB 800.563 (ASFINAG BuS) and PlaPB 800.552 (ASFINAG TIFL). It can be used to implement applications in accordance with ÖNORM EN 12675 and OVE EN 50556.

Available variants

  • ECO-AMPEL-1: Control unit for 1x three-phase traffic light including local control on the device
  • ECO-AMPEL-2: Control unit for 2x three-phase traffic lights including local control on the device
  • (other versions available on request)

Technical Data

  • Compatibility with traffic lights: SWARCO FUTURLED 6 – 230VAC / others on request
  • Power supply: 24 V DC +/-10%
  • Operating voltage (traffic lights): 196..253 V AC (day), 150 V..170 V AC (night, dimmed)
  • Nominal power: min. 8 W/4 W per channel
  • Maximum power: 25 W per channel
  • Monitoring: Operating current monitoring when switched on via current measurement (<75% of nominal current), quiescent current monitoring (cyclical test) when switched off for each signal light below the switch-on voltage
  • Processor: ARM processor
  • Software architecture: C++ firmware, firmware update via RS485
  • Protocols/interfaces: MODBUS RTU/ASCII protocol via RS485
  • Operating temperature: -25°C to +60°C
  • Storage temperature: -25°C to +80°C
  • Humidity: 5% to 90% r.h., non-condensing
  • Housing: Plastic, 8 division units 8TE (8TE)
  • Protection class IP: IP20
  • Equipment protection class: Class 2
  • Approval/marking: CE
  • Housing width x height x depth: 143 mm / 8 TE x 110 mm x 62 mm
  • Weight: 400 g

Detailed specification

  • Status display of the control unit via status LED
  • Traffic light connection Terminal type RM5, cable cross-section: max. 2.5 mm², M3 tightening torque: max. 0.5 Nm
  • Signals Terminal type RM3.5, cable cross-section: max. 1.5 mm², M2 tightening torque: max. 0.2 Nm
  • LED display for the traffic light status for each traffic light (RED, YELLOW, GREEN)
  • Traffic light fault indication by rapid flashing of the corresponding LED
  • Operating mode switch and selection button for manual control (local mode) on the device
  • Blue LED indicators for selection display of manual control on the device
  • Measurement of the AC supply voltage for function monitoring
  • Function check for each light source in the on and off state
  • Integrated fuse for day and night supply
  • Selectable colour sequence types can be parameterised: red-yellow-green, yellow, red, red-yellow, red-green
  • Selectable mode: direct switching of inputs or STVO-compliant colour sequence switching,
  • blocking of invalid traffic light states
  • System parameterisation and status query via Modbus/RS485:
  • #After a power failure and subsequent power restoration, yellow
  • flashing (time parameterisable) and then signal switching as required
  • #Default switching also via Modbus/RS485
  • Flashing synchronised with external flashing clock or internal flashing clock; if the external flashing clock fails, there is an automatic switch to the internal flashing clock

Connection

Supply voltage

  • 24 volts DC
  • 230 V AC for daytime operation
  • 160 V AC for night-time operation

Connection per traffic light

  • Red output
  • Yellow output
  • Green output
  • Neutral conductor

Digital inputs

  • TN ….Day/night
  • BL…External flashing cycle
  • IN…Depending on variant
  • Per traffic light
  • o RT…Red circuit
  • o GE…Yellow circuit
  • o GN…Green circuit
  • o AU…Off

Digital outputs

  • Faults per traffic light
  • o RT…Red lamp fault (low in case of fault)
  • o GE…Yellow lamp fault (low in case of fault)
  • o GN…Green lamp fault (low in case of fault)
  • o AL…Total fault (low in case of fault)
  • o TS…Local operating mode (low in case of local)
  • Operating messages of the switched outputs per traffic light (including current monitoring)
  • o RT…Red
  • o GE…Yellow
  • o GN…Green
  • o TN…Day/night

Assembly

  • Mounting type: Top-hat rail mounting on standard profile rail EN 60715 35×7.5/15 snap-on or rear panel mounting
  • Mounting width x height x depth: 143 mm / 8 TE x 170 mm x 62 mm
  • Distances to be maintained: top/bottom: 30 mm, side: 0 mm

Information brochure as PDF